HVAC Size Calculator
Estimate the air conditioner size a room needs, in BTU, kilowatts and tons, from its area, sun exposure and occupancy.
Rule-of-Thumb Formula: BTU Needed = Room Area (m2) x 550 x Sun Factor + 600 x (People - 2, if positive)
Sun factors: shaded 0.9, average 1.0, sunny 1.2. Also: 12,000 BTU/h = 1 ton of cooling; 1 BTU/h = 0.000293 kW.
Example:
Room = 5 m x 4 m = 20 m2, Average sun, 2 people
BTU = 20 x 550 x 1.0 = 11,000 BTU/h
= 3.22 kW = 0.92 tons, so a standard 12,000 BTU (1 ton) unit fits
This is the common sizing estimate used for single rooms. Whole homes, hot climates, poor insulation, high ceilings and kitchens need a proper load calculation (Manual J in the US) instead of a rule of thumb.
Frequently Asked Questions
Why not just buy the biggest unit?
Oversized air conditioners are a real problem: they blast the room cold quickly, then switch off before removing humidity, leaving the air cold but clammy, and they wear faster from short cycling. Correctly sized units run longer, steadier cycles that dehumidify properly. Slightly under is often more comfortable than far over.
What is a ton of cooling?
An old unit from the ice trade: the cooling delivered by melting one US ton of ice over a day, defined as exactly 12,000 BTU/h. Residential systems are commonly 1.5 to 5 tons. Pakistani and Indian markets often label split ACs directly in tons (1, 1.5, 2), which map to 12,000, 18,000 and 24,000 BTU.