Insulation Calculator
Work out how thick insulation you need to hit a target R-value, for fiberglass, mineral wool, foam boards and more.
Formulas:
- Thickness = R-Value x Lambda (thermal conductivity)
- U-Value = 1 / R-Value (for this single layer)
Example:
Material = fiberglass batt (lambda 0.040)
Target = R 3.0
Thickness = 3.0 x 0.040 = 0.12 m = 120 mm (4.72 inches)
U-Value of the layer = 1 / 3.0 = 0.33 W/m2K
A whole wall's real U-value is better than this layer alone suggests, because plasterboard, blocks, cavities and surface air films all add small resistances of their own: add their R-values to the insulation's before taking 1/R.
Frequently Asked Questions
What R-value should I aim for?
It depends on climate and building rules, but typical guidance: walls R 2.5-3.5 (US R-13 to R-21 in imperial terms), lofts and roofs R 5-7.6, floors R 2.5-3.8. Note the two scales differ: 1 m2K/W = 5.678 imperial R, so this calculator's R 3.0 is about R-17 imperial.
Why do foam boards need so much less thickness?
Their lambda is lower thanks to gas trapped in closed cells: polyurethane at 0.025 reaches R 3.0 in 75 mm, against 120 mm of fiberglass. That thinness is why foam suits tight spaces, at a higher price per square metre and with stricter fire detailing.